Docs menu

Simulator

The simulator is the fastest way to get data flowing - realistic sample events, no real backend. Use it to build and test a surface or warm query before a real source is ready.

Add one

Drag a Simulator onto the canvas (or ask Thinky: "add a simulator for signups") and wire it to a connection. Open the Inspector to configure it.

Configure

SettingWhat it does
NameA label for the simulator
Message Interval (ms)Time between messages - default 30000, minimum 15000
Messages per deviceTotal to send; 0 = keep going
VariablesValues your template can reference (e.g. random ranges)
Message templateThe shape of each event (JSON)

The template names each value with a $.Name placeholder, and each name is defined in Variables - for example a random value in a range. Numbers go unquoted:

{ "signups": $.Signups, "activeUsers": $.ActiveUsers }

with these Variables (the Variables tab shows them as the form described below; this JSON is the value that is stored, and what Thinky sets):

[
  { "name": "Signups", "random": true, "min": 0, "max": 50 },
  { "name": "ActiveUsers", "random": true, "min": 100, "max": 500 }
]

{{...}} placeholders are not supported: they come through as literal text. $.DeviceId, $.Guid, $.Time, $.LocalTime, $.Ticks, $.Epoch and $.MachineName are built in, so you can use them without a Variables entry; they appear in an event only if your template includes them. Nothing is added for you: the device id and the time are in an event only when the template asks for them.

Variable types

In the Variables tab, + Add Variable adds one. Each has a Name and a Type:

TypeWhat it makesFields
Counter (min..max, step)A number that moves from the minimum toward the maximum by the step each messageMin, Max, Step
Random Integer (min..max)A random whole number in the rangeMin, Max
Random Double (min..max)A random decimal in the rangeMin, Max
List (Random)One of your values, picked at randomValues
List (Sequence)Your values in order, one per messageValues
Random String (length)A random stringLength (bytes)

There is no fixed-value type; a List with one value does that job. A new variable starts as a Random Integer from 0 to 100.

The Template tab

The Template tab builds the message field by field, so you do not write the JSON by hand. + Add Field adds a Key, a Type (String, Number, Boolean, Null, Variable or Object) and a Value. Choose Variable to put one of your variables, or a built-in, in that field. A variable that makes numbers is written without quotes and one that makes text is written with them, so the message stays valid.

Start it

Draw a line from the simulator to the connection it should feed; the line is labelled "simulates".

Accepting or saving a simulator writes it to the workspace; it does not start it. Press Deploy to build and start it in your cloud.

A simulator keeps running until you switch it off, or until it has sent its Messages per Device (when that is not 0). Switch it off in its Inspector header and press Deploy to stop it; press Start, then Deploy, to run it again. An idle simulator is not stopped for you: OpenX has a scheduled job that stops one nobody has touched for a long time, but it can only act in a workspace that has enrolled its service account as a member, and OpenX enrols that account nowhere today. A simulator that keeps crashing is not stopped either.

Verify

Watch the Live Stream panel for incoming events (an AI can confirm the connection is healthy with get_stats). With the template above, each event carries values like:

{
  "signups": 12,
  "activeUsers": 318
}

The first event arrives after the first interval (30 seconds by default), once the Deploy has finished starting the simulator. It is not instant.

When it does not work

What you seeWhat to check
No dataThe line from the simulator to the connection is drawn, the simulator is switched on, and Deploy has finished
Data stoppedCheck Messages per Device: a value above 0 ends the sending once it is reached. Check the simulator is still switched on, then Deploy
The wrong data shapeFix the Variables and Template tabs, then Deploy again; a change is not live until it is deployed
Too much dataRaise the Message Interval (ms), or switch the simulator off and Deploy
An interval is refusedThe floor is 15000 ms. The field warns "Minimum interval is 15000 ms." and a lower value is refused with "Message Interval must be at least 15000 ms."

Good habits

  1. Test queries here first. Build warm queries against simulated data before a real source is ready.
  2. Match your real shapes. Give the template the field names your real devices will send, so the queries carry over.
  3. Switch it off when you are done. A running simulator keeps adding data. Switch it off and Deploy.
  4. Write down the variables. Keep the variable names and the template with the connection's notes for your team.

A simulator you write yourself

For a scenario the built-in simulator does not cover (replaying history, a state machine, a failure test), write a device that connects the way a real one does, with the connection's own credentials from Live Devices: open the connection's Connection Info tab and copy Device ConnStr (primary). Any language with an Azure IoT device SDK works. A TypeScript example:

import { Client, Message } from 'azure-iot-device';
import { Mqtt } from 'azure-iot-device-mqtt';

const client = Client.fromConnectionString('YOUR_DEVICE_CONNECTION_STRING', Mqtt);

async function sendTelemetry() {
  const message = {
    deviceId: 'custom-sensor-001',
    temperature: Math.random() * 10 + 65,
    humidity: Math.random() * 20 + 40,
    timestamp: new Date().toISOString(),
  };

  await client.sendEvent(new Message(JSON.stringify(message)));
}

setInterval(sendTelemetry, 30000);

The example is a sketch to adapt; it was not run against a workspace. The built-in simulator's 15 second floor is the simulator's own, so a device you write is not held to it, but every message is a message in your hub, so keep the rate to what you need.